Faults
7
Faults
NOTICE
It is normal for a few drops of water to escape from the
mechanical seal from time to time. This is especially true during
the break-in period.
Depending on the water quality and number of operating hours,
the mechanical seal can begin to leak.
If water leaks constantly, have the mechanical seal replaced
by a qualified technician.
NOTICE
We recommend first informing the swimming pool contractor if
there are irregularities.
7.1
Overview
Problem: Unit cannot be switched on
Possible cause
Positional switch is not
snapped into place.
Problem: Pump is switched off by the built-in or external overload
switch.
Possible cause
Overload.
Media temperature too high.
Problem: Pump seizes.
Possible cause
Mechanical seal is stuck.
34 EN
Solution
Check the cover position.
Solution
Check pump. See point
7.1.1 on page 36.
Wait for the motor winding
to cool down and the
motor protection to turn
back on.
Reduce the media
temperature.
Solution
Turn the motor shaft. See
point 6.1.2 on page 29.
Clean pump and pump
parts.