Installation
5.4.2
Segment display, green and orange LED, fuse
Fig. 12
*RUN* flashes when the microprocessor is working.
*S1* lights up when one of the pump's buttons is pressed.
*P* lights up, the pump should now work and the pump's
protection should be on.
*P* flashes, the pump should be turned on in time mode and the
pump's protection should be on.
*S2* lights up when the LED light button is pressed.
*L* lights up, the LED light should now be on.
*L* flashes, the LED light should now be on in time mode.
Error message
*FL* lights up if there is a short circuit in the cable to the LED
floodlight.
*FL* flashes if there is a disruption in the cable to the LED
floodlight.
Note: The error message *FL* only occurs if the condition "LED
light turned on" is met. Normally, without there being an error in
the lighting circuit, this segment can light up briefly due to the
inrush current in the LED lighting module!
*FV* lights up if the voltage in the microprocessor overloads.
Green and orange LEDs on the circuit board
*green LED* lights up: Power supply present in the circuit board
[Volt].
*orange LED* lights up: Motor protection has triggered (over
current).
Check the motor protection settings.
Circuit board fuse
Replaceable fuse: 3.15 A T
The fuse only needs replacing if the green LED [V] is not lit up.