ABB DCS800 Guide Rapide page 8

Masquer les pouces Voir aussi pour DCS800:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Notes on EMC
You will find further informa-
tion in publication:
Technical Guide chapter:
EMC Compliant Installa-
tion and Configuration for
a Power Drive System
Not applicable
Medium-voltage network
Residential area
Earthed
neutral
Earthed public 400-V
network with neutral
conductor
Mains filter
Line reactor
Converter
Converter
M
M
Operation at public
An isolating transformer
low-voltage network
with an earthed screen
together with other
and earthed iron core
loads of all kinds.
renders mains filter and
line reactor superfluous.
8
3ADW000191R0500 DCS800 Quick guide edisf e
The paragraphs below describe selection of
the electrical components in conformity with
the EMC Guideline.
The aim of the EMC Guideline is, as the name
implies, to achieve electromagnetic compa-
tibility with other products and systems. The
guideline ensures that the emissions from
the product concerned are so low that they
do not impair another product's interference
immunity.
In the context of the EMC Guideline, two
aspects must be borne in mind:
• the product's interference immunity
• the product's actual emissions
First environment (residential area with light industry) with PDS category C2
Not applied, since category C1 (general distribution sales channel) excluded
Supply transformer for a residential
area (rating normally
1,2 MVA)
The EMC Guideline expects EMC to be taken
into account when a product is being developed;
however, EMC cannot be designed in, it can only
be quantitatively measured.
Note on EMC conformity
The conformity procedure is the responsibility of
both the power converter's supplier and the manu-
facturer of the machine or system concerned, in
proportion to their share in expanding the electrical
equipment involved.
satisfied
Medium-voltage network
Light industry
Earthed public 400-V
network with neutral
conductor
Mains filter
Line reactor +
Line reactor
Y-capacitor
Converter
Converter
M
M
M
M
Operation at public
low-voltage network
together with other
loads of all kinds.
satisfied
Supply transformer for a residential
area (rating normally
1.2 MVA)
Earthed
neutral
Earthed public 400-V
network with neutral
conductor
Mains filter
Line reactor
Converter
Converter
M
M
Operation at public
An isolating transformer
low-voltage network
with an earthed screen
together with other
and earthed iron core
loads of all kinds.
renders mains filter and
line reactor superfluous.
Residential area

Publicité

Table des Matières
loading

Table des Matières