Gas Conversions; Lp Gas Conversion - Whirlpool SF114PXSQ1 Instructions D'installation

Masquer les pouces Voir aussi pour SF114PXSQ1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
NOTE: Gas conversions (from natural gas to LP gas or from LP
gas to natural gas) must be done by a qualified person.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Ensure that the manual shutoff valve is in the closed position.
A
B
A. Shutoff valve in "closed" position
B. Gas supply line
C. To range
12
All manuals and user guides at all-guides.com

GAS CONVERSIONS

2. Unplug or disconnect power.
3. Open broiler door and remove broiler pan. The gas pressure
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a flat-
5. Turn the cap over so that LP is visible.
6. Reinstall the cap.
1. Remove burner grate, burner caps, and burners.
C
regulator is located in the back right hand corner of the broiler
compartment.
A. Gas pressure regulator
blade screwdriver.
To Convert Surface Burners
A. Burner cap
B. Burner
A
A
A. Cap
A
B