8. Dismounting, return and disposal

8. Dismounting, return and disposal
WARNING!
Residual media in dismounted instruments can result in
a risk to persons, the environment and equipment. Take
sufficient precautionary measures.
8.1 Dismounting
WARNING!
Risk of burns!
Let the bimetal temperature switch cool down sufficiently
before dismounting! During dismounting there is a risk of
dangerously hot media escaping.
Only disconnect the bimetal temperature switch once the system has
been depressurised!
8.2 Return
WARNING!
Strictly observe the following when shipping the
instrument:
All instruments delivered to WIKA must be free from any
kind of hazardous substances (acids, bases, solutions, etc.).
When returning the instrument, use the original packaging or a
suitable transport packaging.
To avoid damage:
1. Wrap the instrument in an antistatic plastic film.
2. Place the instrument along with shock-absorbent material in the
packaging. Place shock-absorbent material evenly on all sides of
the transport packaging.
3. If possible, place a bag containing a desiccant inside the packaging.
4. Label the shipment as carriage of a highly sensitive measuring
instrument.
WIKA operating instructions model TFS135