Balluff BTL7-S5-M-A/B/Y/Z-NEX-S32/KA Serie Notice D'utilisation page 53

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
10
Type code (continued)
BTL7 USB configurable
Micropulse transducer
SSI interface
Supply voltage:
5 = 10...30 V DC
Data format:
1 = 24 bit, Gray, rising (factory setting)
Resolution:
0 = 1 µm (factory setting)
Synchronous/asynchronous operation:
B = Synchronous operation
Without B = Asynchronous operation
Nominal length (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm
(M0025...M1016: A8, B8, Y8, Z8)
(M0025...M2000: CD)
(M0025...M5500: A, B, Y, Z)
Rod version, fastening:
A = Metric mounting thread M18x1.5, for flat seal, rod diameter 10.2 mm
B = Metric mounting thread M18x1.5, O-ring, rod diameter 10.2 mm
Y = 3/4"-16UNF thread, for flat seal, rod diameter 10.2 mm
Z = 3/4"-16UNF thread, O-ring, rod diameter 10.2 mm
A8 = Metric mounting thread M18x1.5, for flat seal, rod diameter 8 mm
B8 = Metric mounting thread M18x1.5, O-ring, rod diameter 8 mm
Y8 = 3/4"-16UNF thread, for flat seal, rod diameter 8 mm
Z8 = 3/4"-16UNF thread, O-ring, rod diameter 8 mm
CD = Metric mounting thread M22×1.5, O-ring, rod diameter 12.7 mm
Electrical connection:
S32
= 8-pin, M16 plug per IEC 130-9
KA_ _ = Cable, axial (e.g. KA05 = 5 m)
www.balluff.com
BTL7 - S 5 1 0 B - M0500 - B - NEX - S32
Ignition protection
"ec" and "tb"
english
25

Publicité

Table des Matières
loading

Table des Matières