Troubleshooting and fault elimination
Fault response of the Drive PLC
Malfunction
Communication error
Communication error
Log-in not possible
L
i
ibl
PC does not respond
No control signal on the digital
outputs (X2)
No read-in of signals on the digital
inputs (X3)
Fault indications
Display
Error
a
1)
keypad
PC
a
OF
0
No fault
EE
71
System error
a
EF
61
Communication error to AIF
a
EF
62
Communication error to
CAN-IN1 with sync control
16
All manuals and user guides at all-guides.com
Abb. 1-24
Cause
Drive PLC has no supply voltage
No connection between PC and Drive PLC
PC system-bus module 2173IB has no supply
voltage
(LED is OFF on the PC system-bus module)
No termination resistor (120 Ω ) in the system bus
PC system-bus module 2173IB was not initialized
Communication parameter is faulty
The system-bus module was disconnected from
the parallel port (LPT) of the PC during operation
A print job was sent to the interface/port used by
the system-bus module
Missing connection between X1/+ 24 and X1/O24
HIGH level of input signals is too low (< 13 V)
MA DrivePLC DE/EN/FR 1.0
Remedy
Switch on supply voltage
Check system bus wiring
Instructions for PC system-bus module 2173IB
9
Plug in the supply voltage adapter for the DIN/PS2
keyboard connection
Instructions for PC system-bus module 2173IB
5
Follow the switch-on sequence:
1. Plug the PC system-bus module 21731B into
LPT1 or LPTx
2. Switch on the PC
Set the communication parameter correctly
DDS "First steps", Chap. 4.4.2
Restart the PC
Restart the PC, and use the other parallel port
(LPT) for printing
Set up the connection
8
HIGH level of input signals must be between 13 V
... and 30 V
8
Cause
-
Strong interference on control
cables
Ground or earth loops in the wiring
Faulty transmission of control
commands via AIF
CAN-IN1-object receives faulty data
or communication is interrupted
Remedy
-
Shield control cables
Insert the communication module
into the hand terminal
l
Ø
Plug-in connection - bus module
Check FIF
l
Check transmitter
l
Increase monitoring time under
C0357/1 if necessary