INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum
height of 5' (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware. If
installing into drywall, drill 5/32" holes and use the anchors
provided. For pre-wired installations (as in new home
construction), it may be mounted to a single gang box
(Figure 1).
NOTE: The functional temperature range of the door
control is between -4° F (-20° C) and 122° F (50° C).
Scroll speed of display is slower at lower temperatures
although the door control remains fully functional.
CAUTION: Continuous exposure of the door control to
temperatures below -22° F (-30° C) may damage the LCD
screen.
SPECIAL NOTE: Only one 398LMC can be connected to
each garage door opener. If additional wall controls are
desired to operate the same garage door opener, it is
recommended to use model 378LMC wireless wall control
as the secondary door control.
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to the W (2) and
white/red wire to the R (1) (Figure 2).
2. Remove push bar cover by gently prying at the lower/
middle portion of the cover with a small flat-head
screwdriver (Figure 1). Fasten with 6AB x 1-1/4"
self-tapping screws (drywall installation) or 6-32 x 1"
machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude
above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking
plastic housing. DO NOT overtighten.
• Replace cover by inserting top tabs first and then snap
cover in place (Figure 1).
3. (For standard installations ONLY) Run bell wire up
wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. DO NOT pierce
wire with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals on the
motor unit: white to white and white/red to red. To insert
or release wires, push in tab with screwdriver tip
(Figure 3).
NOTE: If you have any trouble with the operation of the
buttons, loosen the top mounting screw. DO NOT connect
power and operate the opener at this time.The trolley will
travel to the full open position but will not return to the
close position until the sensor beam is connected and
properly aligned.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m) and away
from ALL moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
(standard installation)
Screw 6-32x1"
(pre-wired)
Figure 1
REMOVE COVER
PRE-WIRED INSTALLATION
LOC K
LIGHT
LOC K
LIGHT
Figure 2
2-Conductor
Bell Wire
Door
Control
Terminal
Screws
W
R
1
2
(BACK VIEW)
Door Control
Figure 3
Connections
Strip wire 7/16"
7/16" (11 mm)
13
Insulated
Staples
Drywall Anchors
REPLACE COVER
To Replace Insert
Top Tabs First
Push Bar Cover
24 Volt Bell Wire
Push Bar
L O C
K
L O C
K
Lock
Button
Light
Button
To insert or release wire, push
in tab with screwdriver tip
Red
White
Grey
LOC K
LIGHT