Attach The Emergency Release Rope And Handle; Electrical Requirements - LiftMaster ELITE Serie Manuel Du Propriétaire

Masquer les pouces Voir aussi pour ELITE Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION STEP 9
Attach the Emergency Release Rope
and Handle
• Thread one end of the rope through the hole in the top
of the red handle so "NOTICE" reads right side up as
shown. Secure with an overhand knot at least
1" (2.5 cm) from the end of the rope to prevent slipping.
• Thread the other end of the rope through the hole in the
release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet (1.8 m) above
the floor. Ensure that the rope and handle clear the tops
of all vehicles to avoid entanglement. Secure with an
overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.
INSTALLATION STEP 10

Electrical Requirements

To avoid installation difficulties, do not run the opener
at this time.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fit into a grounding type outlet. If
the plug doesn't fit into the outlet you have, contact a
qualified electrician to install the proper outlet.
RIGHT
If permanent wiring is required by your local code,
refer to the following procedure.
To make a permanent connection through the 7/8" (2 cm)
hole in the top of the motor unit:
• Remove the motor unit cover screws and set the cover
aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the brass
terminal; the white (neutral) wire to the screw on the
silver terminal; and the ground wire to the green ground
screw. The opener must be grounded.
• Reinstall the cover.
To avoid installation difficulties, do not run the opener
at this time.
WRONG
To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:
• If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway
is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot
becomes untied, you could fall.
Emergency
Release Handle
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Disconnect ALL electric and battery power BEFORE
performing ANY service or maintenance.
• Garage door installation and wiring MUST be in compliance
with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter or change plug
in ANY way to make it fit outlet. Be sure the opener is
grounded.
PERMANENT WIRING
CONNECTION
Ground Tab
Green
Ground Screw
Ground Wire
15
Overhand
Knot
Trolley
Release
Rope
Arm
Overhand
Knot
Black
Wire
White Wire
Black Wire

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Security+ 3850pc

Table des Matières