DISINFECTING UNIT
6. Fill the water bottle and reservoir ½ full with water and add 1 teaspoon of bleach
to each. Wipe all surfaces on water bottle and cabinet. Let solution stay for 20
minutes, then rinse with water until bleach smell is gone. Dry with clean cloth.
The outside of the unit and water bottle may be wiped down with a soft cloth
dampened with fresh water.
7. Refill unit and re-assemble per ASSEMBLY instructions.
SUMMER STORAGE
1. Clean unit as outlined in Care & Maintenance section.
2. Discard used wick and any water in the reservoir or bottles and allow to dry
thoroughly before storage. Do not store with water inside reservoir or bottles.
3. Do not store unit in an attic or other high-temperature area, as damage will occur.
4. Install new filter at beginning of season.
TROUBLESHOOTING
Trouble
Unit does not operate on
any speed setting
Motor does not Turn On.
Water not draining into
reservoir
Not enough humidity.
Too much humidity.
(condensation becomes
heavy on fold surfaces in
room)
Water leak
Probable Cause
• No power to unit.
• Unit has run out of water – fan
will not operate without water
is present.
• Refill switch
operation/improper
positioning of float assy.
• Check motor/fan operation.
• Water bottle incorrectly
positioned.
• If unit has overheated, motor
temp-sensing fuse may have
tripped.
• Wick is old and ineffective.
• Humidistat is not set high
enough
• Humidistat is set too high.
• Water reservoir may have
been overfilled. Or bottle may
be releasing too much water.
9
Remedy
• Ensure polarized plug is fully inserted in wall
outlet.
• Refill water bottle.
• Ensure float assembly is correctly positioned
as described in "Important Filling Instructions",
• CAUTION: Do not touch the fan when
accomplishing this test, as the motor
may turn on.
• To test the motor, turn unit ON and turn all
dials fully ON.
• Turn the chassis over and insert finger into
tab where float rod is supposed to go. If fan
turns on, the fan and motor are working
correctly.
• Unplug unit. Remove water bottle and
reassemble without water bottle. Turn on
and see if fan comes on. If so, replace
water bottle and continue operation.
• Take unit to authorized service station. DO
NOT ATTEMPT electrical repairs yourself.
• Replace wick when clogged or hardened
with minerals.
• Increase humidity setting on control panel.
• Reduce humidistat setting or increase room
temperature.
• DO NOT OVERFILL bottle and reservoir.
DO NOT puncture bottle to make bottle
drain faster.