Compliance information can be viewed without turning the CPAP on. With the blower OFF (display shows OFF), press the
left or right arrow keys on the keypad to scroll through the information.
Display Example
OFF
Serial Number
HD000005
Adherence Score
83% (25/30)
SmartCode
1FF-FFFF-FWJ
SmartCode
Z7G-7QFM-NWK
SmartCode Data and Adherence Score Information
Your Healthcare provider may contact you to retrieve SmartCode data and Adherence Score information. To display the
SmartCode data, press the LEFT arrow key once. Use the UP arrow or DOWN arrow keys to change the SmartCode
reporting period. Press the LEFT arrow key again to display the Adherence Score.
NOTE–To ensure accurate SmartCode information, the CPAP should remain plugged in and powered during the day. Do
not unplug daily.
Definitions
Not all of the features in the table below are available in all models. Some are optional, and some depend on what your
physician and/or home care provider has selected. The table below shows the items you may see and describes the
feature associated with each item. Also, some features are only available in certain modes or with the DeVilbiss SmartLink
Therapy Management Module. These are noted in the 'Mode' column below. If you do not see some of these options, your
model or configuration does not support them.
Please note that the values displayed are examples only.
Display Example
OFF
P: 5.0
Heat:Off
Set Pressure
10.0 cmH
O
2
Delay Time
45 minutes
Delay Pressure
5.0 cmH
O
2
EN - 18
Description
Blower OFF. The CPAP unit is plugged in to AC or DC power with the blower OFF.
Shows the serial number of the device.
Shows the maximum adherence achieved for any period of thirty consecutive days of
use within a ninety-day time frame. The score represents the percentage of days,
within thirty consecutive days, where usage met or exceeded the 'Usage Threshold.'
SmartCode data is used for therapy management reporting. Therapy information is
1-Day
encoded in a series of letters and numbers and includes a special character for error
checking to ensure accuracy. Use the UP arrow or DOWN arrow keys to change the
Usage
SmartCode reporting period.
Description
Blower OFF. The CPAP unit is plugged in to AC or DC power with the blower OFF.
This is the default screen when the device is turned on. The actual mask pressure
Auto
and heater setting are shown. The displayed pressure may vary slightly while
breathing. If the heater system is not connected, the heat setting will be blank.
This is a prescription setting which controls the operating pressure.
Selectable delay time setting. Your provider has set the delay time.
This is a prescription setting which controls the operating pressure during the delay
time.