Problem
The door does not
Lack of power
open or close
Unlocked engine
Blown line fuse.
Accessories have short
circuit.
The door does not
Check
open.
rotation
The door does not
The
close
activated or damaged
Check
rotation
The
door
moves
The actuator has been
slowly.
unlocked or the power
supply
interrupted.
The door opens or
An accessory connected
closes
when
to the terminals 3 and 5,
connected to 220 V.
5 and 6 or 5 and 7 in
closed position.
Automatic
switch nº 1 enabled.
The door changes
Adjust the level of power
direction during its
movement.
The door stops after
Faulty Hall Sensor
moving about 18 cm
and the sense of the
movement does not
change.
Photocell
and
Wrong position of the
automatic
closing
rotation nº 3 dip-switch
features of the door
are inverted.
The door does not
Wrong programming
close
smoothly
or
automatically.
The
incorporated
Radio selection bridge
receiver
does
not
work
Note: If the door does not work after verifying the above described solutions, it is advisable to replace the electronic
equipment or contact our technical department.
After Sales Service
34-9
02 199 947
mini marathon
Troubleshooting
Troubleshooting
Possible cause
Check the terminals 17 and 18 or 28 and 29 to detect if they have
230 V.
Lock the engine to activate the safety device. Check the led.
Replace the 1 A fuse
Disconnect all the accessories of the terminals 10 (-) and 11 (+)
(there should be a DC voltage of about 24 Vdc) and reconnect
them one by one.
the
sense
of
Press the terminals 5 and 6 with the door halfway along its stroke,
it should then open.
photocell
is
Verify the power supply of the photocell, its connection and the
existence of obstacles. If there is no photocell, bridge the
terminals 4 and 5.
the
sense
of
Press the terminals 5 and 7 with the door halfway along its stroke,
it should then close.
The two or three first manoeuvres will operate slowly so as to
recognize the ends of stroke's butts.
has
been
Connect the accessory to an opened position (pushbutton,
receiver...).
close
Dip-
Disable the automatic close dip switch.
Adjust with the potentiometer. Turn the potentiometer clockwise to
increase the power and counter clockwise to reduce it.
Check the wheels, rollers and any other item that may be causing
friction.
Manually check that the door is moving freely when it is
unblocked.
Replace the Hall effect sensor following the colours and terminals.
* Read appendix note for sensor replacement.
Disconnect the power supply and change the position of the #3
dip-switch.
Press the terminals 5 and 6 with the door half opened and the
door should open.
Program correctly by following the programming instructions of the
stroke
programming must be done with the door closed.
Place the selection bridge internally.