mini marathon
PEDESTRIAN OPENING (microswitch No. 7 ON)
This function allows a pedestrian (partial) opening of the door. Controls programmed to the 2nd Channel must be
used (receiver incorporated) or enter using the open button on terminals 5 and 6 which changes to pedestrian.
Programming the pedestrian stroke: We will only program the pedestrian stroke, the smooth stop and automatic
close time will be the same as previously programmed. If an emitter has been memorised with a pushbutton, then
the next pushbutton on the same emitter activates the pedestrian opening. (If we memorise pushbutton 1, partial
opening = pushbutton 2; if we memorise pushbutton 2, partial opening = pushbutton 3 and so on). To program
the stroke, the door must be completely closed. Press the PROG pushbutton for 1.5 seconds. The red Led will blink,
showing that the equipment is ready to be programmed. Start the opening maneuver by pressing the open
pushbutton or the remote control, when the desired opening is reached press it again to stop the movement and
finalise the pedestrian programming.
SAFETY DEVICE
The automation has an input 21 and 22 for a normally closed contact which will activate when we unlock the door
and move it manually. This inlet operates as a stop pushbutton. Once activated the motor's output is deactivated
and the 'stop' state remains memorised. When we lock the motor again, and press a pushbutton, the first
maneuver is executed slowly until it finds the correct "end of stroke bumper".
SUPPLEMENTS
Radio Card
Allows the use of a radio card to enable remote automation, this action is equivalent to pressing the alternative
pushbutton. Situate the "Radio" bridge externally.
AUXILIARY CONNECTIONS
External Maneuver
The maneuver can be carried out externally when a Normally-Open contact closes between terminals 3 and 5
using a pushbutton or by way of a relay output of a radio control receiver. In this case the contact acts as an
Alternative Pushbutton. If a pushbutton is connected between 6 and 5, it acts as an Open Pushbutton. If we
connect a pushbutton between 7 and 5, it acts as a Close Pushbutton.In some automations it is possible that the
door has incorporated another pedestrian access door. To protect this door which on opening the sliding door
does not work, it will be necessary to install an end of stroke between terminals 7 and 5; this end of stroke will be in
Normally-Open contact that will be closed on opening the pedestrian access door.
Flash Light Lamp
Between terminals 13 and 14 a Normally-Open and electricity-free contact is facilitated, which is closed while the
door is in operation or in Mode B, 3 seconds before the automatic closing of the door.
24v Output
There is an output of 24Vcc. and 0.15A between terminals 10(-) and 11(+) to power auxiliary elements such as a
photocell.
Garage Lights
Between terminals 15 and 16, there is an output of 220V a.c. which operates when the door opens, and stops 3
minutes later.
Photocell
The photocell, with its normally closed contact, is connected between terminals 4 and 5. It is activated only when
the door closes, preventing it from closing if it is completely open or reversing the operation if it is closing.
Photocell Test (optional)
If microswitch no. 5 is set to OFF, then at the start of each maneuver the main panel will run a check on the
photocell.
Safety Position 1 (nc) / 8.2 Kohm Range (microswitch No. 4)
Microswitch no. 4 selects the safety input from the photocell when opening, or the resistive band when closing.