SELECTING THE TYPE OF OPERATION
Microswitch no. 2 allows the selection of the type of operation.
Switch 2 OFF, mode A
. There is no pre-warning on the flash light lamp before beginning the maneuver.
. Each operation on the maneuver input causes it to be reversed
. The close safety causes re-opening.
Switch 2 ON, mode B
. Flash light lamp pre-warning before each maneuver.
. Close safety causes a slight delay and delays the door.
. Incorporation of alternative maneuver.
TERMINALS DESCRIPTION
1. Ground (Mesh)
2. Aerial (Live)
3. Alternative pushbutton (N.O.)
4. Safety position (N.C.) (photocell)
5. Pushbuttons and photocell common wire
6. Open pushbutton (N.O.)
7. Close pushbutton (N.O.)
8. Photocell test
9. Safety position 1 (N.C.) / 8.2 KOhm range
10.0 Volt complementary power supply
11.24 Volt complementary power supply
12.Battery charger
13.Flash light position. Free of tension
14.Flash light position. Free of tension
15.220V Garage light output
FUNCTIONS OF THE DIP-SWITCHES
DIP-1
ON
-
OFF
-
DIP-2
ON
-
OFF
-
DIP-3
ON
-
OFF
-
DIP-4
ON
-
OFF
-
DIP-5
ON
-
OFF
-
DIP-6
ON
-
OFF
-
DIP-7
ON
-
OFF
-
DIP-8
ON
-
OFF
-
mini marathon
16.220V Garage light output
17.220V AC Power supply
18.220V AC Power supply
19.24 Volt AC Power supply
20.24 Volt AC Power supply
21.Safety device (N.C.) Motor
22.Motor common safety device
23.Sensor power supply, positive (brown)
24.Sensor signal (green)
25.Sensor power supply, negative (white)
26.Motor (blue)
27.Motor (red)
28.220V (primary of the transformer)
29.220V (primary of the transformer)
Note:
The board closes automatically
There is no automatic close
Operation mode B
Operation mode A
Changes motor direction
Motor direction is the stated one
Terminal 9 acts as a safety band
Terminal 9 acts as safety position 1
Photocell test disabled
Photocell test enabled
Programming via radio enabled
Programming via radio disabled
Pedestrian opening
Normal opening
Variable smooth stop programming (variable slow down)
Smooth stop set at 20cm (slow down at 20cm)
automatismos pujol - 34 - english
N.O. Normally Open
N.C. Normally Closed