Télécharger Imprimer la page

wallas 85 Dt Mode D'emploi page 73

Masquer les pouces Voir aussi pour 85 Dt:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 161
D10191
85 Dt / Nordic Dt
Installation
Closable lead-through 2466
The cap of the closable lead-through must be detached for installation and seal
maintenance by pressing the spring indicated by the arrow in with, for instance, a
screwdriver. Take care not to let the screwdriver slip as the spring is very stiff. Hold
the cap with your other hand when pressing in the spring. When the spring is down,
pull the cap gently out of the frame. When assembling the lead-through, ensure
that the order of the parts is correct. Also make sure that the spring goes in the cor-
rect hole in the cap. Otherwise, the lead-through cannot be closed.
2466
Closable lead-through.
Maintenance
To keep the seals from hardening, lubricate
them yearly with a heat-resistant petroleum
jelly.
Check that closeable fi tting is open before starting the device.
Package contents
2466
1 pcs
Closable lead-through
1 pcs
Spacing tube
1 pcs
Accessory bag 17678
4 pcs
8 pcs
4 pcs
4 pcs
1 pcs
1 pcs
1 pcs
Seals
Fastening screw M5 x 85 mm
Nut M5
Washer 5,3 x 15 mm
Washer 5,3 x 10 mm
Hose binder 20 - 32 mm
Hose binder 32 - 50 mm
Gasket
- 73 -
en
en
Cap
Frame
490539

Publicité

loading

Ce manuel est également adapté pour:

Nordic dt