Télécharger Imprimer la page

wallas 85 Dt Mode D'emploi page 55

Masquer les pouces Voir aussi pour 85 Dt:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 161
D80101
85 Dt / Nordic Dt
Technical information
Stove operation
The 85 Dt / Nordic Dt is a safe diesel stove with no open fl ame. The stove is
equipped with a single burner which burns either diesel oil or light furnace oil. The
stove takes the air needed for the burning process from the boat and discharges
the resultant smoke with a combustion air blower. This means that, when the stove
is being used, the air in the boat circulates and stays fresh and dry. The steam in
the fl ue gas does not remain in the boat and increase interior humidity.
The fuel pump in the stove dispenses fuel, and the electronics control the combus-
tion air and the amount of fuel automatically to keep the fl ame of the burner clean.
When the stove is switched on, the glow plug in the burner ignites the fuel that has
been pumped into the burner. The glow time is fi xed: it begins and ends automati-
cally.
The heat sensor in the stove detects the heat of the fl ame and lights the red LED
light to signal that the fl ame has been ignited.
The heat which is released as the fuel burns is transferred into the ceramic stove
top. The left side of the stove top is hotter, as the burner is located under it. The
power of the stove can be adjusted steplessly. The control adjusts both sides of the
stove simultaneously.
When the stove is switched off, it cools down automatically. The cooling function
ventilates the burner and discharges the fl ue gases generated during the switch-off
outside the boat.
The stove lends itself extremely well to cooking and warming up all kinds of foods.
It has been manufactured entirely from stainless materials.
Technical information
Fuel
Operating voltage
Consumption
Heating power
Power consumption
Measurements
Weight
Max. permissible length of the fl ue gas
pipe
Max. permissible length of the fuel hose
Minimum size of the replacement air
opening
Suitable fl ue gas lead-throughs
85 Dt
Diesel oil, light furnace oil
0,2...0,35 A
(when ignited ca. 5-10 min. 8 - 10 A)
456 x 306 x 150 mm
Appr. 8 kg
100 cm
16 square inches
- 55 -
en
en
Nordic Dt
12 V DC
0,09 - 0,19 l/h
900 - 1900 W
0,55...0,85 A
456 x 343 x 208 mm
Appr. 12 kg
4 m
13'
8 m
26'
150 cm
2
2
24 square inches
5100, 1066, 2466
490539