10. Faults, causes and remedies

If the fault cannot be solved, please contact
SALMSON customer services.
Faults
One or two pumps fail to prime
One pump fails to run
POMPES SALMSON SAS 11/2011
9. Maintenance
- No particular maintenance is recommended for
the booster when operating.
- Motor bearings are greased for life-time.
- No maintenance for the mechanical seal when
operating.
- In long period of frost and stop of the pump, it is
recommended to drain the pump by screwing off
the bottom plug.
ATTENTION! Fill in the pump before any new
start.
Causes
Air leak at suction
Foot-valve strainer not tight or obstruc-
ted
Large losses of head at suction
Public water pressure too low or zero
Suction head too high
Suction piping obstructed or valve on
suction manifold closed
Pumps turn in the reverse direction
(three-phase)
Thermal relay tripped
Magnetic circuit breaker tripped
Pump shaft blocked
Winding fault
Contactor coil blown
Remedies
Check tightness of all suction pipe con-
nections.
Check if the tank suction strainer is
covered with water
Check tightness of the valve, replace it if
necessary
Calculate the losses of head and make
sure they are compatible with the pump
NSPH
If it recurs, it is recommended to use a tank
Be sure that the minimum water level of
the tank is compatible with the NPSH of
the pumps
Check valve opening and clean the
piping if necessary
Cross 2 supply wires on the motor termi-
nal blocks
The pump "fault" indicator on the control
box must be lit. Check the setting of the
current
Switch it again. If tripping recurs, check
the output current of the motor concer-
ned. If this current is much higher than
the one mentioned on the motor type
plate, the circuit breaker is defective and
shall be replaced
Switch off the electric supply of the con-
trol box and then check the shaft turns
freely. If it is blocked, dismantle the
pump
Disconnect the terminal block of the
motor concerned. Check the network at
the terminals and the stator insulation.
Replace the motor if necessary
Replace it