PROBLEMS
Radiators cold in winter
Hot water is not provided
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator's electrical regulator may not be compatible with the stove's electronics. The higher the quality of
the generator, the greater the chance that it is compatible with the stove
7. ELECTRICAL DIAGRAM
REASON
1. room thermostat (local or remote)
set too low if remote thermostat, check
if it is defective.
2. circulator does not run because
blocked.
3. Circulator does not run.
4. Radiator have air in them
Circulator (pump) blocked
[ EN ● 37 ]
KEN002PW18 25.11.2019
SOLUTION
1. Set to higher temperature or
replace ( if remote).
2. Free up the circulator by removing
the plug and turning the shaft with
screwdriver.
3. Check the electrical connections of
the circulator; replace if necessary
4. Vent the radiators
Free the circulator (pump)
Version: 2.0