Télécharger Imprimer la page

Nemaxx PW18 Manuel D'utilisation page 32

Publicité

Les langues disponibles

Les langues disponibles

5.1.2 CHECK EVERY 2/3 DAYS
The frequency of cleaning depends on the type of installation/
connection to the flue pipe (e.g. more frequent with horizontal
connection, less frequent with vertical connection), on the num-
ber of working hours, level of power and type of fuel used. Clean
and empty the ash tray "G" being careful with hot ash.
The ash must be completely cold for a vacuum cleaner to be
used to remove it. Only use models suited to sucking ashes. We
recommend emptying the ash pan at intervals of no more
than 2 or 3 days.
Once the process is complete, place the ash tray back under the
grate and make sure that it is inserted correctly.
5.1.3. CLEANING THE GLASS
For cleaning the ceramic glass, the use of a dry brush is recom-
mended, or if it is very dirty, the special spray detergent, applying
a small quantity then cleaning with a cloth.
IMPORTANT!
Do not use abrasive products and do not spray
the cleaning product on the glass of the painted
parts or on the gaskets of the fire door (ceramic
fiber cord).
5.1.4 CLEANING OF STAINLESS STEEL AND SATIN-FINISH SURFACES
Normally these surfaces do not need to be treated, but if they do, avoid cleaning them with abrasive materials.
For surfaces in stainless and satin brushed steel we recommend cleaning with a paper towel or a clean dry
cloth moistened with a detergent based on non-ionic surfactants (< 5%). A spray glass cleaner may be used.
5.1.5. CLEANING OF PAINTED PARTS
Do not clean the painted parts with wet rags when the unit is in operation or hot to prevent thermal shock to the
paint which may cause it to detach. Do not use abrasive or aggressive products or materials. Clean with damp
cotton or paper towels.
The silicon paints used on nemaxx products possess technical characteristics that make them
resistant to very high temperatures. There is however a physical limit (380°-400°) beyond which the
paint begins to fade or (over 450°) to vitrify; it may then flake and detach from the steel surface. If this
happens, it means that temperatures have been reached that are far above those at which the unit
should operate properly.
5.2 CLEANING TO BE PERFORMED BY SPECIALIZED TECHNICIAN
5.2.1 CLEANING THE HEAT EXCHANGER AND THE PIPE UNIT
Halfway through the winter, but especially in the spring, you will need to clean the compartment where dischar-
ge smoke passes. This cleaning must be done in order to remove all combustion residues before time and
humidity let them harden and make them difficult to remove.
[ EN ● 32 ]
Version: 2.0
KEN002PW18 25.11.2019

Publicité

loading

Produits Connexes pour Nemaxx PW18