Télécharger Imprimer la page

Nemaxx PW18 Manuel D'utilisation page 34

Publicité

Les langues disponibles

Les langues disponibles

If the fuel is left in the hopper, it may get damp, stick together, and be difficult to light at the beginning of the next season If
the stove is removed form its place of installation it MUST be placed in a location that is protected from atmospheric
agents. If pressing the main switch (located on the back of the stove) does not make the control panel display light up, it
could mean that the service fuse needs replacing .
ATTENTION: Disconnect the electrical cable.
On the rear of the stove there is a fuse holding compartment which is located underneath the supply socket. With a
screwdriver open the cover of the fuse holding compartment, and replace the fuse if necessary (3.15 AT delayed type).
Plug the unit back in and press the main switch. If the problem persists or occurs again, contact service or your spezialized
technician .
IMPORTANT!
The check of the internal electromechanical components must be carried out only by qualified personnel
with technical knowledge of electricity and combustion.
5.3 CHECK OF INTERNAL COMPONENTS
We recommend that an annual maintenance service is carried out, preferably under a programmed service contract. The
essential part of this service is a visual and functional check on the following components:
● Reduction motor
● Smoke expulsion fan
● Smoke sensor
● Heat-exchanger fan
● Ignition sparkplug
● Resettable pellet thermostat
● Room temperature sensor
● Motherboard / service card
● Fuses protecting panel - motherboard - services card
● Wiring
The following is a summary of the checks and/or maintenance tasks which are indispensable for the correct operation of the stove
PARTS / INTERVAL
Grate
Ash drawer
Glass
Lower compartment
Complete exchanger
Smoke duct
Ash drawer door gasket
Internal parts
Flue pipe
Circulation pump
Plate heat exchanger
Plumbing components
Electro-mechanical components
Every day
Every 2-3 days
[ EN ● 34 ]
KEN002PW18 25.11.2019
Every 60-90 days
Every year
Version: 2.0