Antenna Installation; Manual Programming - BFT DEIMOS Série Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Wires having very low safety voltage (24V) must be physically separated
from low voltage wires, otherwise they must be adequately insulated with
additional insulation of at least 1 mm.
The wires must be secured by additional fixing elements next to the terminals,
for example by means of clips, avoiding any contact between the cables and
the motor case.
All the connection cables must be kept at an adequate distance from the
dissipator.
Connect the yellow/green wire of the power supply mains to the earth terminal
of the appliance (see Fig.15 ref.A).
WARNING! For connection to the mains, use a multipolar cable with a
minimum of 3x1.5mm
2
cross section and complying with the previou-
sly mentioned regulations. For example, if the cable is out side (in the
open), it has to be at least equal to H07RN-F, but if it is on the inside
(or outside but placed in a plastic cable cannel) it has to be or at least
egual to H05VV-F with section 3x1.5mm
clearly separated from connections having very low safety voltage (24V).
JP1
1-2
Power supply 230V +/- 10% 50/60 Hz (Neutral to terminal 1).
3-4-5 Connection to motor M (terminal 4 common, terminals 3-5 motor and
capacitor drive).
1-4
Connection to blinker and electric lock 230V mod. EBP.
JP2
7-8
START pushbutton or key selector (N.O.).
7-9
STOP pushbutton (N.C.). If not used, leave the bridge connected.
7-10
Photocell input or pneumatic edge (N.C.). If not used, leave the bridge
connected.
7-11
Opening limit switch (N.C.). If not used, leave the bridge connected.
7-12
Closing limit switch (N.C.). If not used, leave the bridge connected.
13-14 Output 24Va.c. supply to photocells or other devices.
15-16 Output for gate-open warning light outputor alternatively 2nd radio
channel.
17-18 Antenna input for radio-receiver plug-in board (20 braid–19 signal).
JP3
19-20 Pedestrian input (N.O.)
JP4 Radio-receiver board connector, 1-2 channels (Fig.21).
5) LED (Fig.21)
The ALPHA control unit is provided with a series of self-diagnosis leds which
control all the functions.
DL1: Incorporated radio receiver LED
DL2: START - Start - goes on when a start command is given.
DL3: STOP - Stop - goes off when a start command is given.
DL4: PHOT - Photocell - goes off when the photocells are not aligned or in
the presence of obstacles.
DL5: SWO - Goes off when the opening limit switch is operated.
DL6: SWC - Goes off when the closing limit switch is operated.
6) DIP-SWITCH SELECTION (Fig.21)
DIP1)
TCA [ON] - Automatic closing time TCA.
ON:
Activates automatic closing
OFF: Excludes automatic closing
DIP2)
FCH [ON] - Photocells.
ON:
Photocells are only active in the closing phase.
OFF: Photocells are active both in the closing and opening phase.
DIP3)
BLI - Blocks impulses.
ON:
START commands are not accepted during the opening phase.
OFF: START commands are accepted during the opening phase.
DIP4)
3P/4P - 3 Steps/4 Steps
ON:
Enables 3-step logic.
OFF: Enables 4-step logic.
DIP5)
CODE FIX – Fixed code.
ON:
Activates incorporated receiver in fixed code mode.
OFF: Activates incorporated receiver in rolling-code mode.
DIP6)
RADIO LEARN - Radio transmitter programming
ON:
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
INSTALLATION MANUAL
2
. Keep the mains connections
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new tran-
smitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio. The transmitters can only
be memorised using the appropriate Radio menu.
DIP7)
SCA – Gate-open warning light or 2nd radio channel.(Fig. 24).
OFF: Activates relay output in Gate-open warning light mode.
ON:
Activates relay output as 2nd radio channel.
DIP8)
FAST CLOSE
ON
Closes the gate after photocell disengagement, before waiting for the
end of the TCA set.
OFF Command not entered.
7) TRIMMER ADJUSTMENT (Fig.21)
TCA (Dip1 ON).
It is used to set the automatic closing time, after which the gate closes
automatically (adjustable from 0 to 90 sec.).
TW
It is used to set the motor working time, after which the motor stop (adjustable
from 0 to 90 sec.). When using electrical limit switches, increase the motor
stopping time by a few seconds with respect to the leaf closing time.
8) INTEGRATED RECEIVER TECHNICAL SPECIFICATION
Receiver output channels:
-
output channel 1, if activated, controls a START command.
-
output channel 2, if activated, controls the excitation of the 2nd radio
channel relay for 1s.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with

ANTENNA INSTALLATION

Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a
more suitable position.
9) PROGRAMMING
Transmitter storage can be carried out in manual mode, or by means of the
universal palmtop programmer
the "collective receivers" mode, as well as manage the complete installation
database using the EEdbase software.

10) MANUAL PROGRAMMING

In the case of standard installations where no advanced functions are required,
it is possible to proceed to manual storage of the transmitters
1) If you wish the transmitter T key to be memorised as Start, press the
SW1 button on the control unit, otherwise if you wish the transmitter key
to be memorise as second radio channel, press the SW2 button on the
control unit.
2) When the DL1 LED blinks, press the transmitter P1 hidden key, and the
DL1 LED will stay on permanently.
3) Press the key to be memorised on the transmitter, LED DL1 will start
blinking again.
4) To memorise another transmitter, repeat steps 2) and 3).
5) To exit the storage mode, wait until the LED is switched off completely.
IMPORTANT NOTE: ATTACH THE ADHESIVE KEY LABEL TO THE FIRST
MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the key
code to the receiver; this code is necessary in order to carry out subsequent
cloning of the radio transmitters.
10.1) CONTROL UNIT MEMORY CANCELLATION
In order to cancel the control unit memory completely, simultaneously press
for 10 seconds the SW1 and SW2 buttons on the control unit (DL1 LED
blinking). Correct memory cancellation will be indicated by the DL1 LED
staying on permanently.
To exit the storage mode, wait until the LED is switched off completely.
11) RECEIVER CONFIGURATION
The on-board receiver combines characteristics of utmost safety in copying
variable code (rolling code) coding with the convenience of carrying out
transmitter "cloning" operations thanks to an exclusive system.
DEIMOS - DEIMOS 700 - DEIMOS 800F Ver. 03 -
ENGLISH
.
which allows you to create installations in
15

Publicité

Table des Matières
loading

Table des Matières