INDOOR UNITS INSTALLATION
d. Mount the electrical box in its new location (right side)
and fasten it with the 2 fixing screws.
e. Make sure that the entire electrical hose is properly
secured and exits through the right-hand side wall
opening.
!
C A U T I O N
The electrical hose must not be tightened or forced at any point in its route.
f. Mount the lower panel of the indoor unit and secure it
with the 3 fixing screws.
g. Mount the cover of the electrical box and fasten it with
the 2 fastening screws.
14
PMML0528 rev.1 - 02/2021

Mount the electrical box on the wall
a. Cut the bottom, pre-cut part of the electrical box wall
passage and move the electrical hose so that it comes
out the bottom of the electrical box.
b. Present the electrical box in its final location on the wall
and make sure that the electrical hose is attached to the
wall free of obstacles in its path.
!
C A U T I O N
The electrical hose must not be tightened or forced at any point in its route.
c. Secure the electrical box to the wall with 2 retaining
screws.
d. Mount the cover of the electrical box and secure it with
the 2 retaining screws.