Press the PEAK/INRUSH button (L) for 2 seconds to return
to normal operation. The INRUSH indicator (7) no longer
appears.
AC voltage measurement
WARNING
make sure the probe tips are touching the metal contacts inside
the outlet. Do not assume the outlet is not live if there is no
voltage reading. Use other methods to test the outlet if there is
any uncertainty.
Insert the black connector lead (S) into the COM (black)
input terminal (I) and the red connector lead (S) into the V
(red) terminal (M).
Set the function switch (K) to the
Connect the test probes (R) in parallel to the circuit under
test.
Read the voltage on the display (F).
Measuring AC voltage peaks
In AC voltage measurement mode, press the PEAK/
INRUSH button (L) to measure the maximum peak and
minimum peak values.
Press the PEAK/INRUSH button (L) to switch between the
maximum (MAX) and minimum (MIN) measured value. The
appropriate MAX/MIN indicator (8) appears on the display.
Risk of electric shock! When testing outlets,
position.