4.12 Setting reception mode

The control unit is set for the radio control
Press"+" to display "5"
Note: in order to exit the programming and save the parameters push P button for 5 seconds.

4.13 Photocell Function Setting

(Default setting on "0")
Press"+" to display "6"
Photocell is always active
in closing
Through this function with the door closed and photocell interrupted, it is possible to enable/disable the opening command
Note: in order to exit the programming and save the parameters push P button for 5 seconds.

4.14 Setting of the duration of automatic closure

(Default settlng:"off")
Press"+" to display "7"
Value
Time
Note: in order to exit the programming and save the parameters push P button for 5 seconds.

4.15 Setting of alarm for 2000 operating cycles

(Default setting :"off")
Press"+" to display "8"
Silencing the acoustic alarm: power off, then power on again, or press the door control keys + or - for 5 seconds
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
22
of all Key
Automation transmitters.
Press "P", on the display '1"
flashes, to indicate that the set
radio decoding is ROLLING CODE
(default setting); if 2 is selected on
the display the set radio decoding
is FIX CODE
Press"+", the display shows 1, to
indicate that the photocell is ac-
tive during opening
Press "P" to show "0", the func-
tion is not active (default setting)
0
1
2
not active
5 sec
10 sec
Press "P". The display shows 0
to indicate that the function is not
active (default setting)
Press "+" o "-" to select the
desired type of decoding
Press "P", the display shows 0,
to indicate that the photocell is
not active during opening
(default setting)
Press"+" to show "1" and activate
the function. The duration auto-
matic closing is 5 seconds.
3
4
5
20 sec
30 sec
60 sec
Press "+". The display shows 1 to
indicate that the function is active
Press the key "P" to show "5",
and save the settings.
Press "P" again to save the
settings
Press "+",or "-" to select the dura-
tion following the table below
Press "P" again to save the set-
tings.
6
7
8
120 sec
180 sec
240 sec
Press "P" again to save the
settings