6.3 OIL FILL
6.3.1 Gear box and hydraulic lift sump.
Check level every 50 hours with the dipstick n.13 fig.1.
It is advisable to use AGIP SUPER TRACTOR UNIVERSAL SAE 15W/40 oil
Change oil every 800 hours. Quantity required: about 29 Kg.
To drain oil: plugs n.1 fig.18-19-20.
To fill with oil: plug n.13 fig.1.
6.3.2 Front transmission oil
It is advisable to use AGIP SUPER TRACTOR UNIVERSAL SAE 15W/40 oil
change oil every 800 hours. Quantity required: about 6 Kg.
To drain oil: plug n.2 fig.21 and n.1 fig.22
To add oil: plug n.1 fig.21.
6.3.3 Cleaning hydraulic lift oil filter.
Clean this filter every 400 hours and with every oil change. Drain the oil, remove the
filter (n.1 fig.23), wash it with petrol or naphta, dry and replace in container. Clean
the filter after the first 50 hours.
6.4 RADIATOR
As needed clean the core with compressed air from the inside towards the outside.
Every 8-10 hours check the cooling liquid level in the expansion tank.1 fig.24. The
level should be at the halfway mark on the reservoir with the engine cold.
It is advisable to use FIAT PARAFLU 11 coolant.
Change coolant every 2 years. Quantity required: about 11 liters.
To drain coolant: plug on bottom left of radiator.
To add coolant: pour into expansion tank n.1 fig.24.
Never remove radiator cap when engine is hot.
6.5 AIR FILTER
Check filter clog status on the corresponding indicator on the air in-take manifold
(n.1 fig.25). When the view section of the indicator is almost completely red. clean
the filter. this operation should also be done whenever warning light (n.2 fig.3 - n.3
fig.32) comes on.
66