Lenze L-force EMF2113IB Instructions De Montage page 55

Modules de communication interbus
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Features
Communication
medium
Network topology
Maximum number of
controllers
Baud rate
Specification of the transmission cable
General characteristics
Cable type
Number of conductors
Conductor cross−section
DC cable resistance
Impedance (characteristic)
Capacitance per unit length
EDKMF2113 DE/EN/FR 5.1
RS485
Ring
Dependent on INTERBUS master (e.g. Phoenix Contact G4 master).
For the following data, always the smaller value applies dependent on the
fact, whether PCP communication is available or not:
l
with PCP communication:
l
without PCP communication:
l
500 kbits/s with a distance of 400 m between neighbouring nodes
l
2 Mbits/s with a distance of 150 m between neighbouring nodes
Sold by the meter,
(e.g. PHOENIX CONTACT: IBS RBC Meter−T, Order No.
28 06 28 6)
3 × 2, twisted pairs, with shared shield
> 0.2 mm
< 96
l
l
< 60 nF/km (f = 800 Hz)
l
Electrical installation
62 or
256 / number of PCD
2
W
/km
W ±
120
20 % (f = 64 kHz)
W ±
W
100
15
(f > 1 MHz)
4
Wiring