Electrical installation
Wiring
Item
Element
1
INTERBUS master with
interface module
2
INTERBUS loop bus
terminal
3
Remote bus
Fig. 2 pos. 3
3.1
Remote bus module
3.2
Remote bus cable
4
INTERBUS loop,
peripheral bus
Fig. 2 pos. 4
4.1
INTERBUS loop
module
4.2
INTERBUS loop cable
54
Explanation
The bus system is a master−slave system, i.e. an INTERBUS master is
connected to several field devices (slaves).
The bus terminal connects a remote bus to a peripheral bus.
The following connections are possible with remote buses:
l
Connections between INTERBUS master interface module and
first bus terminal or first 2113 communication module
l
Connection between bus terminal and 2113 communication
module
l
Connection between two 2113 communication modules
Node in the remote bus, e.g. Lenze controller with INTERBUS module
(slave). Networking does not require bus terminals.
Connects the INTERBUS master interface module with the bus
terminals and/or the remote bus modules.
Connection in a peripheral−bus station
A peripheral−bus station consists of:
l
a bus terminal (Fig. 2 pos. 2)
l
up to eight peripheral bus modules (Fig. 2 pos. 3)
Node in the INTERBUS loop; e.g. Lenze controller with INTERBUS loop
module 2112
Connection within the loop
l