Télécharger Imprimer la page

Festo SPC200 Mode D'emploi page 19

Masquer les pouces Voir aussi pour SPC200:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
4.3 Connecting the proportional directional control valve
The valve connection provides the power supply for the
valve and provides the control voltage for the slide valve
setting.
Please note
Use only the original type KMPYE−... cable.
Pin assignment and wire colours for the
KMPYE−... cable
2: 0 V
3: 0 V
4: Setpoint voltage U(s)
5: GND
6: n.c., not connected
7: 24 V supply to valve
1: 24 V supply to valve
n.c, not connected
Festo SPC−AIF−MTS−2 0611NH English
4
brown
green
yellow
grey
pink
white
blue
red
6
5
7
1
3
2
Socket for (MPYE)
valve on the
KMPYE−... cable
2
3
2
3
4
n.c.
1
n.c.
1
4
19

Publicité

loading

Ce manuel est également adapté pour:

Spc-aif-mts-2