Specifications; Heating Specifications; General Instructions - Napoleon NPS45 Instructions D'installation Et D'opération

Poêle aux granules, encastré aux granules
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.2

specifications

Electrical Rating
Watts During Start-Up Sequence
Watts During Operation
NPS45 Width
NPS45 Height
NPS45 Depth
Weight
Exhaust Collar
Intake Collar
NPS45 Hopper Capacity
NPI45 Hopper Capacity
Minimum Appliance Opening Size
* In order to install, flashing flush to finished wall and centered within the opening the front opening of the appliance or
enclosure must be 32 5/8" (829mm) wide.

2.2.1 heating specifications

Approximate Maximum Heating Capacity (in square feet)*
Burn Rate (Pounds per Hour)**
BTU/hr**
Maximum Burn Time on Low Burn**
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is
also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20%
depending on fuel quality may occur.
2.3

general instructions

ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA C22.1
CANADIAN ELECTRIC CODE (IN CANADA) OR THE ANSI/NFPA NO. 70 NATIONAL ELECTRIC CODE
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" (121.9cm)
Thank you for purchasing a Wolf Steel Ltd. Pellet Appliance. This appliance is designed for use with Pelletized
Wood Only.
Please read this entire manual before installation and use of this pellet fuel-burning room appliance. Failure to
follow these instructions could result in property damage, bodily injury or even death.
Keep this manual handy for future reference.
This Pellet Appliance, when installed, must be electrically grounded in accordance with the local codes, or
IN THE UNITED STATES.
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
FROM THE FRONT FACE OF THE APPLIANCE.
115 Volts, 3.6 Amps, 60Hz
400 (approximately)
180 (approximately)
22 3/8" (568mm)
30 1/2" (775mm)
26 5/8" (676mm)
210 Pounds (95kg)
3" (76mm)
2" (51mm)
55 Pounds (25kg)
45 Pounds (20kg)
Front: 32 5/8" (829mm)* W x 20 5/8" (532mm) H x 14 1/4" (362mm)
D Back: 20 3/8" (518mm) W
800 to 2000 Sq. Feet (243-610 Sq. Meters)
1.0 to 5.0
8500 to 42500
55 Hours (NPS45), 45 Hours (NPI45)
WARNING
!
9
EN
W415-1472 / B / 02.05.18