13.0 troubleshooting

TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
WHEN CHECKING CONNECTIONS, INSTALLING JUMPER WIRES (FOR TEST PURPOSES ONLY) OR
REPLACING COMPONENTS, UNPLUG APPLIANCE FROM THE RECEPTACLE TO PREVENT
NOTE: Many of the following tests will require that the side panels are removed from the appliance
or the insert be removed from its cavity to access the components. Before troubleshooting always
confi rm that all components are clean and free of ash build up.
SYMPTOM
APPLIANCE SHUTS OFF AND THE #2 LIGHT FLASHES
Vacuum hose or fi ttings
are blocked
The air inlet, burnpot,
interior combustion air
chambers, combustion
blower or exhaust pipe
are blocked with ash or
foreign material.
The fi rebox is not
properly sealed.
Vent pipe is incorrectly
installed.
The vacuum switch wire
connections are bad.
The gray wires are
pulled loose at the
connector on the wiring
harness.
Combustion blower
failure.
Control board not
sending power to
combustion blower.
Control board not
sending power to
vacuum switch
Vacuum switch has
failed (very rare).
WARNING
!
DO NOT USE ABRASIVE CLEANERS.
ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT.
-
Unhook the air hose from the vacuum switch and blow through it. If air
fl ows freely, the hose and tube are fi ne. If air will not fl ow through the hose,
use a wire coat hanger to clear the blockage.
-
Follow all cleaning procedures in the maintenance section of the manual.
-
Make sure the door is closed and that the gasket is in good shape. If the
ash door has a latch, make sure the ash door is properly latched and the
gasket is sealing well.
-
Check to make sure the vent pipe installation meets the criteria in the
manual.
-
Check the connectors that attach the blue wires to the vacuum switch.
-
Check to see if the blue wires are loose at the connector.
-
With the appliance on, check to see if the combustion blower is running. If
it is not, you will need to check for power going to the combustion blower.
It should be at 115 volts. If there is power, the blower is defective. If there
is not, see the next step.
-
If there is no current going to the combustion blower, check all wire
connections. If all wire connections are properly connected, you have a
defective control board.
-
There should be a 5-volt current (approximately) going to the vacuum
switch after the appliance has been on for 30 seconds.
-
To test the vacuum switch, you will need to disconnect the air hose from
the body of the appliance. With the other end still attached to the vacuum
switch, very gently suck on the loose end of the hose (Hint: remove the
hose from the vacuum switch and the appliance fi rst to see if it is clear). If
you hear a click, the vacuum switch is working. CAUTION: TOO MUCH
VACUUM CAN DAMAGE THE VACUUM SWITCH.