Residual Risk; Falling Parts; Rotating Parts; Stability - BADU Block Multi 100 Traduction Du Instruction D'utilisation Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 124
Pos: 48 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Restrisiken @ 0\mod_1427723332615_370.docx @ 26639 @ 2 @ 1
2.7

Residual risk

Pos: 49 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Herabfallende Teile Multi @ 4\mod_1449223317742_370.docx @ 54387 @ 3 @ 1
2.7.1

Falling parts

The lifting hooks on the motor are designed for the weight of the
motor. The lifting hooks can break if the complete pump unit is
attached.
Attach the pump unit consisting of motor, pump and filter
housing (where necessary) on both the motor and the pump
sides. See chapter 4.2 on page 20.
Only use hoisting and load-bearing equipment which is
suitable and technically sound.
Do not stand under suspended loads.
Pos: 51 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Rotierende Teile - GSA @ 1\mod_1429096331026_370.docx @ 27892 @ 3 @ 1
2.7.2

Rotating parts

There is a risk of shearing and crushing due to exposed rotating
parts.
Only perform servicing when the pump/unit is not in
operation.
Prior to servicing, ensure the pump/unit cannot be switched
back on.
Immediately after finishing servicing, reattach or reactivate all
protective equipment.
Pos: 52 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Standsicherheit Multi @ 4\mod_1449223352677_370.docx @ 54403 @ 3 @ 1
2.7.3

Stability

Ensure sufficient stability of the pump/unit. There is a danger
of crushing due to tilting or falling over.
Pos: 54 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Elektrische Energie @ 0\mod_1427779167394_370.docx @ 26692 @ 3 @ 1
2.7.4

Electrical energy

There is an increased risk of electric shock when working on the
electrical system due to the humid environment.
Electrical protective earth conductors which were not installed
correctly can also result in electric shocks, for example oxidation
or cable breakage.
Observe VDE and utility company regulations.
Build swimming pools and their protection according to
DIN VDE 0100-702.
Before working on the electrical system, take the following
measures:
– Disconnect system from the power supply.
04/2016
Safety
EN 11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Block multi 250Normblock multi 100Normblock multi 250

Table des Matières