3
Technical data
Electrical data
3.2
Electrical data
Input data
Basis of the data
Mains
3/PE AC
3/PE AC
3/PE AC
Type
E94ASxE0324
E94ASxE0474
E94ASxE0594
E94ASxE0864
E94ASxE1044
Temperature in the control cabinet
Output data
Type
E94ASxE0324
E94ASxE0474
E94ASxE0594
E94ASxE0864
E94ASxE1044
Temperature in the control cabinet
Type
E94ASxE0324
E94ASxE0474
E94ASxE0594
E94ASxE0864
E94ASxE1044
Rated values for internal brake chopper
Type
E94ASxE0324
E94ASxE0474
E94ASxE0594
E94ASxE0864
E94ASxE1044
58
Voltage
U
[V]
LN
230
180 - 0 % ... 264 + 0 %
400
320 - 0 % ... 440 + 0 %
500
400 - 0 % ... 550 + 0 %
Voltage
Frequency
[V]
[Hz]
230/400/500
50/60
230/400/500
50/60
230/400/500
50/60
230/400/500
50/60
230/400/500
50/60
Voltage
Frequency
[V]
[Hz]
0 - 230/400/500
0 - 480
0 - 230/400/500
0 - 480
0 - 230/400/500
0 - 480
0 - 230/400/500
0 - 480
0 - 230/400/500
0 - 480
when operating with rated output current I
750
1050
1122
1500
1800
Switching
Minimum
threshold
brake resistor
(adjustable)
U
[V]
R
[Ω]
BRmax
Bmin
390/790
9/18.0
390/790
7.5/15.0
390/790
7.5/15.0
390/790
3.8/7.5
390/790
3.8/7.5
Voltage range
U
[V]
LN
Current [A]
max. +45 °C
max. +55 °C
29/29/26
43/43/39
47/47/41
79/79/70
95/95/84
1)
Current [A]
max. +45 °C
max. +55 °C
32/32/28
47/47/41.1
35.3/35.3/30.8
59/59/51.6
44.3/44.3/38.7
86/86/75.3
64.5/64.5/56.4
104/104/91
Power loss P
[W]
V
when controller is inhibited
aN
Peak current
Peak braking
power
I
[A]
P
[kW]
BRmax
BRmax
43.3/43.9
16.9/34.7
52.0/52.7
20.3/41.6
52.0/52.7
20.3/41.6
102.6/105.3
40.0/83.2
102.6/105.3
40.0/83.2
Frequency range
f [Hz]
45 - 0 % ... 65 + 0 %
45 - 0 % ... 65 + 0 %
45 - 0 % ... 65 + 0 %
Number of
phases
22/22/20
3
32/32/29
3
35/35/31
3
59/59/52
3
71/71/63
3
Number of
phases
24/24/21
3
3
3
3
78/78/68.3
3
75
100
Continuous
Continuous
current
braking
power
RMS
I
[A]
P
[kW]
BRd
Bd
28.5/28.9
7.3/15
37.9/38.4
10.7/22.0
44.2/44.8
14.6/30.0
75.5/77.5
21.6/45.0
83.5/85.7
26.5/55.0
EDK94SH104 DE/EN/FR/ES/IT 4.1