Technical Data; General Data And Operating Conditions - Lenz E94ASHE Single Drive HighLine Série Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3

Technical data

General data and operating conditions

3
Technical data
3.1
General data and operating conditions
Information on mains
Mains types
Noise emission
Noise immunity
Conformity and approval
Conformity
CE
Approval
UL
Protection of persons and devices
Enclosure
Insulation resistance
Insulation of control
circuits
Short-circuit strength
Motor protective
measures against
Discharge current
Cyclic mains switching
56
With earthed 
Unrestricted use
point
IT systems
Observe instructions on specific measures!
EN 61800-3
Cable-guided, motor cable length up to 50 m: category C2
EN 61800-3
Category C3
73/23/EEC
Low-Voltage Directive
UL 508C
Power Conversion Equipment, 1D74, File No. 132659
EN 60529
IP 20
NEMA 250
Protection against contact to
type 1
EN 61800-5-1
Overvoltage category III
Reduction from 2000 m amsl onwards: Overvoltage category
II
EN 61800-5-1
Safe mains isolation by double/reinforced insulation.
EN 61800-5-1
Motor connection: with restrictions, fault acknowledgement
required
Control connections: without restrictions
Short circuit
Earth fault
Overvoltage
Motor stalling
Motor overtemperature
(PTC or thermal contact, I
EN 61800-5-1
> 3.5 mA
Cyclic mains switching of 5-times in 5 minutes permissible
without restrictions.
Not in the wiring range of
the terminals on the
motor side
2
t monitoring)
Observe regulations and
safety instructions!
EDK94SH104 DE/EN/FR/ES/IT 4.1

Publicité

Table des Matières
loading

Produits Connexes pour Lenz E94ASHE Single Drive HighLine Série

Table des Matières