Setup functions on pulse panel
Parameter Name
Nr
PostGasTime
1
PreGasTime
2
HotStartLevel
11
HotStartTime 2T
12
CraterFillLevel
14
CraterFillSlope
15
CreepStartLevel
17
CreepStartSlope
18
DoubleFrequency 21
DoubleAmpiltude 22
StartPower
31
PulseCurrent
33
ArcLength
41
AdjRange
Calibration
42
WFS
51
Gun
53
GunRemote
54
Display reset
81
time
PRG INFO - feeld
82
selection
Restore
99
12 – KEMPACT™ PULSE 2800 AUTOMOTIVE / 0709
Display 1-MIG Pulsed
MIG
PoG
X
X
PrG
X
X
Hot
X
X
H2t
X
X
CFL
X
X
CFS
X
X
CSL
X
X
CSS
X
X
dFr
-
-
dA
-
-
StP
X
X
PuC
X
ALr
X
X
CAL
X
X
FS
Gun
GrE
dLY
X
X
diS
X
X
FAC
X
Factory
Unit
Explanation
value
Curve
s
PostGas time 0.0...9.9 s
Curve
s
PreGas time, functions by
2T 0.0...9.9 s
30
%
Hot start ratio to welding
power 50...+75%
2
s
2T Hot start timer 0.1-9.9 s
30
%
Welding end level 10-90 %
1
s/10m
Wire slowing-down
1...20 s/10m
Syn
Wire speed start value
10...90
0
s/10m
Wire speed up time
0.1...5 s/10m
-
-
-
-
-
-
0
Start power control
-9...0...+9
0
%
Pulse top current control
10...+15%
0
%
Arc length adjustment
range 50...+75%
1
V/100A Setting mid value of arc
length fi ne adjustment
0.0...10.0 V/100A
18
m/min
Wire feed maximum
18 or 25 m/min
On
liquidcooled thermal
protection on/off
On
Disabling of gun remote
control automatic
identifi cation
5
s
1...20 s
1
1,2,3
OFF
Restoring factory settings
(OFF=no reset,
Pan=panel and setup
ALL= also memory
channels)