Ca-Mi NEW ASKIR 30 Mode D'emploi page 12

Masquer les pouces Voir aussi pour NEW ASKIR 30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Place the unit on a flat, horizontal surface
Connect one end of the short silicon tube, with antibacterial filter, to the suction connector on the lid of the jar.
The other tube already connected to the filter has to be connected to the "VACUUM" jar outlet, where has been fixed the red float
(security float). When the 90% of the volume of the jar is reached there is the activation of the security float (the float close the
aspiration connector on the jar) to avoid liquid penetration inside the device.
WARNING: Ensure that the FLUID SIDE or IN marker on the filter is on the side facing the collection jar lid and fitted into the "VACUUM".
A wrong connection causes immediate destruction in case of contact with sucked liquids.
Connect the long silicone tube to the "PATIENT" jar outlet
Connect the other end of the long silicon tube to the probe plastic connector, then connect the suction probe to it.
Connect the power cord to the device then connect the plug to the electrical mains supply.
Push switch on position I to start suction.
Unscrew the lid of the jar and fill the jar 1/3 full or ordinary water (this assists the unit to reach peak vacuum performance and makes
clean-up easier) then re-screw the lid on the jar correctly.
During operation the jar has to be in vertical position to avoid overflow valve to cut off aspiration. Should this happen, switch off the
device and disconnect the tube from the jar cover (from "VACUUM" outlet).
Once finished push switch on O position and unplug.
Remove the accessories and clean.
MAKE SURE THAT CHILDREN AND/OR MENTALLY ILL PEOPLE DO NOT USE THE DEVICE WITHOUT ADULT
UNDER NEW EUROPEAN RULES, CA-MI REQUIRES THE FOLLOWING PROCEDURES TO BE CARRIED OUT TO PROTECT THE INSTRUMENT AND THE
SAFETY OF ALL WHO COME IN CONTACT WITH IT.
CA-MI warrants it's product for 24 months after purchasing date.
Before returning an instrument for repair, the external surfaces and all accessories MUST be carefully disinfected with a cloth soaked in methylated spirits
or hypochlorite-based solution. The instrument and accessories should then be placed in a bag with a note outlining the disinfection undertaken.
Failure to follow this procedure will result in the instrument being returned to the purchaser unrepaired.
Instruments returned for repair MUST be accompanied by a description of the problem. CA-MI will not be responsible for damage caused through
improper use. To avoid such damage, please read the instruction carefully.
Where CA-MI determines that an instrument is faulty, a replacement will be provided only if a SALES RECEIPT and STAMPED GUARANTEE are
provided. CA-MI will not be responsible for damage accessories. These may be replaced at the customer's expence.
INSTRUCTION FOR USE
NEVER USE THE DEVICE WITHOUT JAR AND / OR PROTECTION FILTER
SURVEILLANCE
ALWAYS PLACE THE DEVICE IN POSITIONS FOR EASY DISCONNECTION
RULES FOR RETURNING AND REPAIRING
12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

New askir 20

Table des Matières