machine cool down after use.
• After each use the tank must be vented and the moisture collected in the tank
must be bled. Not bleeding the tank can lead to leakage and may cause a
dangerous situation.
• Check that the electric circuit is adequately protected and that it corresponds
with the power, voltage and frequency of the motor. Check that there is a
ground connection and a regulation differential switch upstream.
• Use cables with an adequate section and avoid use of free and inadequately
insulated connections.
• Never open the pushbutton box on the motor. Should this be necessary,
contact a qualified electrician.
• Make sure that the machine and the cable never come in contact with water.
• Treat the power cable with care. Do not attempt to move the machine by pulling
the cable. Do not yank the cable to unplug it; keep the cable away from
excessive heat, oil and sharp objects.
• Never leave the machine unattended with the power supply "on". Also
disconnect the power cable when:
- you leave the machine, even for a short time
- not in use
- carrying out maintenance work
- changing attachment or moving the machine.
• WARNING: the warnings, cautions and instructions discussed in this
instruction manual cannot cover all possible conditions and situations that
may occur. It must be understood by the operator that common sense and
caution are factors which cannot be built into this product, but must be
supplied by the operator.
• Only those persons who are aware of how to use the compressor by having
read this manual, should use the machine. Injudicious use may cause danger.
Danger plates (page 49)
The plates fitted on the compressor unit are part of the machine; they have been
applied for safety purposes and must not be removed or spoiled for any reason.

3.0 PLACING

The AIRPRESS compressor is equiped with wheels and a pull bow (L models with
carrying handle) making the machine very mobile. When placing the machine, take
care of a horizontal position. If not placed horizontal, severe damage may occur
due to lack of lubrication. The engine should get sufficient cooling air, so never
cover the ventilation openings.
If the compressor should get a permanent place, place it in a dustfree room.
Never place the compressor in a room where will be sprayed. A paint spray clogs
namely the airfilter and also deposits on the compressor. Mind that the draintap for
condensation water and the level gauge will always remain attainable. We suggest
to leave a space of aproximately 30 cm for ventilation and maintenance.
28