3.0 PLACING

The compressor should be placed in such way that all points, destined to carry it
will really do so. Take also care of a horizontal position. The engine should get
sufficient cooling air; so never cover the ventilating openings.
Place the compressor in a cool dustfree space. Never place the compressor in a
room where will be sprayed. Paint spray will clog the air filter and will also deposit
on the compressor.
Mind that the draintap for condensation water (10), the oil drain plug (11) and the
oil plug (13) will always remain attainable. We suggest to leave a space of
aproximately 50 cm for ventilation and maintenance.
Notice: Insufficient air supply, too high temperature and fouling of the air
filter reduce the efficiency of the compressor considerably.

3.1 ELECTRIC CONNECTION

At the factory the machine is already fully equipped with cables. The machine
now has to be connected to your own electricity supply. Connect the machine to a
separate group. Beware that voltage and amperage of your electric circuit meet
the needs of the motor. Use only cables with the right diameter. The factory
suggests to use cables of at least 2.5 qmm, length max. 10 m.
Before first use first read chapters 3.2 and 4.0.

3.2 AIR CONNECTION

Best use for connection of the compressor to an air circuit a flexible hose, to
isolate fibrations from the machine. The coupling No 6 is a universal
Orion/Airpress quick coupling.