3.0 PLACING

The compressor should be placed in such way that all points, destined to carry it will
really do so. Take also care of a horizontal position. The engine should get sufficient
cooling air; so never cover the ventilating openings.
Place the compressor in a cool dustfree space. Never place the compressor in a
room where will be sprayed. Paint spray will clog the air filter and will also deposit on
the compressor.
Mind that the draintap for condensation water (10), the oil drain plug (11) and the oil
plug (13) will always remain attainable. We suggest to leave a space of aproximately
50 cm for ventilation and maintenance.
Notice: Insufficient air supply, too high temperature and fouling of the air filter
reduce the efficiency of the compressor considerably.

3.1 ELECTRIC CONNECTION

At the factory the machine is already fully equipped with cables. The machine now
has to be connected to your own electricity supply. Connect the machine to a
separate group. Beware that voltage and amperage of your electric circuit meet the
needs of the motor. Use only cables with the right diameter. The factory suggests to
use cables of at least 2.5 qmm, length max. 10 m.
Before first use first read chapters 3.2 and 4.0.

3.2 AIR CONNECTION

Best use for connection of the compressor to an air circuit a flexible hose, to isolate
fibrations from the machine. The coupling No 6 is a universal Orion/Airpress quick
coupling.