Minimum safety distances

Minimum internal distances
The installation niche must be made of non-flammable materi-
al. The minimum distances between the fireplace and walls are
shown in the drawing:
Minimum internal distances
A) Upper
200 mm
B) Rear and
50 mm
lateral
Minimum external distances
Flammable objects and walls can not be placed within the high-
lighted area in the drawing:
Minimum external distances
C) Floor
150 mm
D) Front
800 mm
E) Lateral
150 mm

Air grills

To avoid overheating of the unit, air recirculation with one or more openings must be created in the upper and lower part of the
cladding.
Observe the minimum dimensions shown in the drawing:
Air grills
F) Upper
Hot air outlet
G) Lower
Cold air inlet
H) Laterals
(in case of installation
on a support)
Use and maintenance manual R 1000 Pro
500 cm
2
500 cm
2
2 x 250 cm
2
B
F
G
A
C
E
D
E
F
H