Sanitising Procedure - Following Cleaning Procedure
1) D i l u t e a p p r o x i m a t e l y 1 5 m l o r 1 t b s o f a 5 . 2 5 % s o d i u m
hypochlorite solution (chlorine bleach) with 3.8 litres of warm
water. Using a chlorine test strip or other method, confirm that you
have a concentration of about 200 ppm.
2) Soak the removed parts from step 17 above in a clean container
containing the sanitising solution. After allowing the parts to soak
for 10 minutes, wash them with the solution. Also wash the bin
liner, bracket (L) (R) with the solution.
3) Discard the sanitising solution and rinse the parts thoroughly with
water.
4) Replace the removed parts in their correct positions in the reverse
order of which they were removed.
5) Same as step 1.
6) Pour the sanitising solution into the water tank, and allow the
sanitiser to sit for 10 minutes.
7) Move the control switch to the "SERVICE" position and the service
switch to the "WASH" position.
8) After 15 minutes, move the control switch to the "OFF" position.
9) Move the control switch to the "SERVICE" position and the service
switch to the "DRAIN" position.
10) After 2 minutes, move the control switch to the "OFF" position.
11) Repeat steps 5 through 10 one time. Repeat steps 9 through 12 in
the cleaning procedure three times to rinse thoroughly.
12) Flush the storage bin with water.
13) Move the control switch to the "ICE" position, and start the
automatic icemaking process.
14) Close the door. Replace the louver in its correct position.
Cube Guide
Water Tank
* The bin control switch is
accessible by removing
the water tank.
Fig. 7
2. BEFORE CALLING A SERVICE AGENT
Do not damage the refrigerant circuit.
If the icemaker does not work properly or does not work at all, before
calling for service, check that:
* The power is supplied to the unit.
* The control switch is in the "ICE" position.
* The water is turned on.
* The air filter is clean.
For further assistance or advice, contact your local Hoshizaki service
agent.
3. WARRANTY
Hoshizaki warrants to the original owner/user that all Hoshizaki
branded products shall be free of defects in material and/or
workmanship for the duration of the "warranty period". The warranty
shall be effective for two years from the date of installation.
Hoshizaki's liability under the terms of the warranty are limited and
shall exclude routine servicing, cleaning, essential maintenance and/
or repairs occasioned by misuse and installations not in accordance
with Hoshizaki guidelines.
Warranty repairs should be completed by an approved Hoshizaki
dealer or service agency using genuine Hoshizaki components.
To obtain full details of your warranty and approved service agency,
please contact your dealer/supplier, or the nearest Hoshizaki Service
office:
Europe
U.K./Ireland - Hoshizaki UK
TEL : +44 (0)845 456 0585
FAX : +44 (0)1462 499080
Holland - Hoshizaki Europe
TEL : +31 (0)20 6918499
FAX : +31 (0)20 6918768
Belgium/Luxemburg - Hoshizaki Belgium
TEL : +32 (0)2 7123030
FAX : +32 (0)2 7123031
Germany/Switzerland/Austria - Hoshizaki Deutschland
TEL : +49 (0)2154 92810
FAX : +49 (0)2154 928128
France - Hoshizaki France
TEL : +33 (0)1 48639380
FAX : +33 (0)1 48639388
Spain/Portugal - Hoshizaki Iberia
TEL: +34 (0)93 4780952
FAX: +34 (0)93 4780900
Other countries - Hoshizaki Europe
TEL : +31 (0)20 6918499 or +44 (0)845 456 0585
FAX : +31 (0)20 6918768 or +44 (0)1462 499080
Other than Europe
Hoshizaki Singapore
TEL : +65 6225 2612
FAX : +65 6225 3219
Hoshizaki Lancer
TEL : +61 8 8268 1388
FAX : +61 8 8268 1978
Hoshizaki Suzhou
TEL : +86 512 62807850
FAX : +86 512 62807860
5
ENGLISH
WARNING

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Km-125a

Table des Matières