4. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the national
and local electrical code requirements. To prevent possible
severe electrical shock to individuals or extensive damage to
equipment, install a proper earth wire to the icemaker. Remove
the plug from the mains socket before any maintenance, repairs
or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 10A supply. The
electrical supply must be protected by a suitable circuit breaker.
* The main control box fuse is rated at 5A, 250V and should only be
replaced by a qualified service engineer.
* Usually an electrical permit and services of a licensed electrician are
required.
* If the supply cord is damaged, it must be replaced by a replacement
cord available from Hoshizaki Parts/Service Centres.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may
not correspond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to
the terminal in the plug which is marked with the letter E or by the
symbol
or coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal which is marked
with the letter N or coloured Black. The wire which is coloured
Brown must be connected to the terminal which is marked with the
letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for
the plug supplied with your product, the plug must be removed (cut
off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord,
it must be disposed of. There should be no attempt to reuse it.
Inserting such a plug into a socket elsewhere presents a serious risk
of electrical shock.
* The non-rewirable plug must never be used without a fuse cover
being fitted.
The correct replacement for the detachable fuse cover is identifiable
from the manufacturer's reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki
Parts/Service Centres.
Fuses should be rated at 10A and approved to BS 1362.
5. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Only potable water should be used for this icemaker.
* The connections to the mains water supply must be made in
accordance with the countries' current requirements of the Water
Supply or Water Fittings Regulations.
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and
maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78 MPa
(8 bar), use a pressure reducing valve. Do NOT throttle back the
supply tap.
* Be sure to use the new hose-sets supplied with the appliance. Do
not reuse any old hose-sets.
* A plumbing permit and services of a licensed plumber may be
required in some areas.
* Water should drain into an open trap.
* The icemaker drain is gravity flow, so ensure drain pipe has an
adequate pitch or fall.
* To prevent a backflow into the storage bin, the outlet hose must be
laid as shown in Fig. 2.
GOOD
Downgrade
Fig. 2
1) Attach the free end of inlet hose to the stop valve (Fig. 4), noting
washer is correctly positioned. Hand tighten sufficiently to provide
leak free joint. It is a wise precaution to have the stop valve within
easy reach.
2) Wrap P.T.F.E. tape around the hose adapter fitting, and screw the
hose adapter into the drain outlet of the icemaker. Hand tighten
grey flexible outlet hose (accessory) onto the hose adapter as
indicated (Fig. 3). The pipe can be cut to length as necessary to
suit position of main drain. To prevent water leaks, secure the outlet
hose to the drain outlet by using a hose band.
Note: Jointing compounds should be approved and suitable for
potable water use.
Inlet Hose
2
BAD
Upgrade
BAD
Hose Adapter
Outlet Hose
Fig. 3
Inlet Hose
Washer
Stop Valve
Fig. 4