Normal Operation
The default operating mode keeps the dehumidifier
running at its maximum capacity. This is ideal for
most restoration application. To control humidity at a
specific level, choose Humidistat Mode, described be-
low.
Humidistat Mode
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
MENU SELECTION to toggle be-
tween ON and OFF. NOTE: When in Humidistat mode,
the unit will display HUMIDISTAT on the top line during
normal operation rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode.
Press
MENU SELECTION to change RH value. Each
press of the button increases the setting by 5% incre-
ments, cycling through 90%RH and starting again at
40%RH.
TEMP UNITS
C° >
Shows current temperature scale. Press
LECTION to select Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
SELECTION to select Spanish, German, French or Eng-
lish.
COIL TEMP
00°C
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
This function is not used on the Revolution.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
AT THE END OF THE JOB
To reduce the possibility of drips when moving the unit,
follow these additional steps to ensure that all water is
removed from the unit.
NOTICE: To ensure all water is removed from the Revo-
lution, the unit will complete the defrost cycle even if the
unit is turned off. If the unit is unplugged during the de-
frost cycle, excessive water may accumulate in the unit
07-01899B F413-230V EUUK 2013-12
Warranty 07-00427 DoC 07-00289
and may drip out when you move the unit. If the defrost
cycle is interrupted in this way, note that the unit will dis-
play the message POWER FAILURE the next time it is
powered up. To clear the message, press the MENU
SELECTION key.
NOTICE: To ensure the condensate tank empties com-
pletely while purging, make sure the unit is positioned
horizontally on a flat surface.
1. If the unit is in a defrost cycle, wait until the unit has
returned to normal operating mode before proceeding.
To check, review the control panel. The control panel will
show one of the following:
Defrost in progress:
Display mode when unit is in defrost mode. XX indicates
the minutes remaining on the defrost cycle.
Shutdown Sequence
Display mode when unit in defrost and unit is powered
down (shut off by user). Unit will complete the defrost
cycle to remove any built-up ice then purge the pump.
MENU SE-
XX indicates the minutes remaining on the defrost cycle.
Normal Display:
MENU
Wait until the control shows the normal display before
proceeding.
2. Gently rock the machine to ensure any water remain-
ing on interior surfaces falls into the sump area.
3. Press the
complete, turn the unit off.
4. Remove the external drain hose, drain it carefully, coil
it and secure it with one of the Velcro straps provided on
the side of the unit.
5. Unplug power cord from power supply, coil neatly, coil
it and secure it with one of the Velcro straps provided on
the side of the unit (see Fig. A).
TRANSPORTATION AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
• Do not expose the control panel to moisture, snow
• Protect from freezing.
• Store and transport securely to avoid any damaging
4
UNIT ON 00 HRS
DEFROST XX
WAIT FOR
DEFROST XX
UNIT ON 00 HRS
INLET XX° C
PURGE key. When the purge cycle is
or rain.
impact to internal parts.
Dri-Eaz Products, Ltd.