9.2.16 Video Analysis Page

The device can be configured to emit motion
detection alarms using ONVIF events.
This page allows you to define the following settings:
• Enable emission of motion detection events.
• Configure the algorithm sensitivity level.
Fig. 55

9.2.17 Tools Page

From menu entry Tools it is possible to re-set the
predefined values for the entire configuration of
device or only for a number of specific sections.
This section:
• Update the firmware of the device.
• Restart the device.
Fig. 56
36

9.2.18 Factory Default

Before doing any technical work or
maintenance on the device, make sure that
potentially explosive atmosphere is not
present.
If the access password is no longer
available, follow the procedure to reset to
default factory settings.
To restore the factory settings relative to the network,
user access and camera configuration follow this
procedure:
• Switch off the unit.
• Open the connection compartment.
• Power the unit. Wait for 2 minutes.
• Press and hold the reset button for 15 seconds. (P1,
6.4 Connector board description, page 18).
• Switch off the unit.
• Close the connection compartment.
• Power the unit.
• Access the following IP address: 192.168.10.100.
It is also possible to perform the reset in remote
mode. Follow the procedure below:
• Power the unit. Wait for 2 minutes.
• Connect the reset contact on the serial line
connector (J9, RST) with the alarm contact on the
relay and alarm connector (J3, AL5) (6.8 Alarm and
relay connections, page 20).
• Wait 15 seconds.
• Open the previously closed contact.
• Switch off the unit.
• Power the unit.
• Access the following IP address: 192.168.10.100.