7. Starting, operation
With a line transformer you realise the mandatory galvanic isolation of the voltage
and current supply between hazardous and non-hazardous areas and ensure the
safety connection data.
Power supply
UB+/Sig+
Positive supply / measurement connection
OV/Sig-
Negative supply / measurement connection
L-Connector,
DIN EN 175301-803, Form A
for conducter cross section up
to max. 1.5 mm², conducter
outer diameter 6 to 8 mm
(ship approval: 10 to 14 mm),
IP 65
Non hazardous
Hazardous
area
(classified) area
Betriebsanleitung/Operating instructions/Mode d'emploi/Instrucciones de servicio
2-wire
Model PEX10, PEX11, PEX15
Flying leads with 1.5 m of cable,
conducter cross section up to max. 0.5 mm², AWG
20 with end splices,
conducter outer diameter 6.8 mm
IP 67
IP 68, zero/span not adjustable
IP 68, zero/span adjustable
Non hazardous
area
Load (e.g. display)
Hazardous
(classified) area
brown
green
screen / case