Notices On Use; Doffing The Facepiece - Dräger FPS 7000 Notice D'utilisation

Masquer les pouces Voir aussi pour FPS 7000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Alternative fit check, which allows you to keep the lung demand valve
connected to the self-contained breathing apparatus and the
facepiece:
Close cylinder valve.
Inhale all air from the system, then carry out leak test.
Open the cylinder valve again.

Notices on use

Report to operation only with an airtight facepiece!
If the facepiece is not airtight, this could result in physical injury.
Low Temperatures
Use "kp comfort" anti-fog agent to prevent fogging of the visor.
High temperatures/variation in thermal stress
In case of any damage, e.g. bubbles in the visor, immediately leave
the danger zone. Failures of the facepiece increase the risk of
injury.
The coating may dissolve in some places on visors marked with
PCas. The facepiece is fully serviceable until the end of the
operation. Replace visor after use.
Chemicals
Some substances may be absorbed by the material of the facepiece
and may possibly diffuse into it. For further information please
contact your local Dräger representative.
Potentially explosive areas
Use a water screen or treat the facepiece meticulously with antistatic
spray.
8
CAUTION
CAUTION

Doffing the facepiece

If fitted, open the button protector.
Press the button on the connection piece and simultaneously pull
the lung demand valve out of the connection piece.
Push the sliding buckles of the bottom head harness forward with
your thumb and loosen the straps (Figure E).
Pull the facepiece away from the face over the head.
Do not pull the facepiece at the connection piece to prevent
damaging the facepiece!
Use Instructions for NIOSH-approved full facepieces
CAUTION

Publicité

Table des Matières
loading

Table des Matières