Daily Inspection

Check before use every time:
1
Seal is undamaged.
— Lid is closed and handle bolted.
— No cracks, holes or other
damage more than 1.5 mm in
depth can be seen on the casing.
2
Indicator is dark blue in colour.
If there is a significant loss of
blue colour (50 % of the particles
have changed colour from dark
blue to pink or neutral) the oxy-
gen self-rescuer must not be
used any more.
Pack the oxygen self-rescuer and send to Dräger.

Assembly of Shoulder Strap

Oxy K 30 HS/HS KD
To complete the training unit ready for use mount the shoulder
strap
:
as shown
Loop shoulder strap in back plate
Loop short end of shoulder strap
in slot of back plate (1).
Loop shoulder strap in clamp
buckle
Mount the ends of shoulder strap
into the clamp buckle and pull the
ends of shoulder straps as far as
possible (2).
Close clamp buckle (3).

Advice on Use

— Do not open the oxygen self-rescuer until it is required for use.
Humidity in the atmosphere may penetrate the open oxygen self-
rescuer and impair its function.
— Inspect the oxygen self-rescuer daily.
— Use the oxygen self-rescuer only once.
— To avoid risk of fire make sure that no flammable materials (petrol,
grease, solvents etc.) can get into the oxygen self-rescuer before
or during operation.
There is also danger of ignition if the oxygen-releasing chemicals
come into contact with combustible substances such as coal
when the oxygen self-rescuer is damaged.
Opened units are classified as used and it is not allowed to store
them. They have to be recycled (see "Disposal" on page 12).
For routine training purposes, use the training unit
Oxy K 30 HWT/HST (see "Order List" on page 15).
1) not CE-approved.
2
1
1
2
3
1)

Donning Procedure

If the oxygen self-rescuer is not donned correctly, there could be
a delay in starting in an emergency
Perform the following donning steps according to the
described order.
Oxy K 30 HW
Opening the case
Take the yellow opener.
Move the handle downwards until
lid
removes from oxygen self-
rescuer.
Remove lid.
Putting on the unit
Take neck strap and pull out
oxygen self-rescuer with the
second hand at the housing
carrying frame upwards from
holder.
Turn the oxygen self-rescuer in a
way that the housing carrying
frame shows to the chest.
Pull red rubber neck band over
head and hang around neck.
Pull the neck straps to position
the oxygen self-rescuer correctly.
Oxy K 30 HS/HS KD
Opening the case
Take the yellow opener.
Move the yellow opener away
from body until lid removes from
oxygen
self-rescuer.
Remove the lid from oxygen
self-rescuer in straight direction
(straight away from body).
Remove lid.
.