At The End Of A Cleaning Session; Maintenance, Cleaning And Decontamination; Main And Hepa Filter Disassembly And Replacement - Nilfisk 118 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

At the end of a cleaning session

1 - Turn off the vacuum cleaner and remove the plug
from the socket.
2 - Wind the connection cable (fig. 14).
3 - Empty the container as described in the "Emptying
the container" paragraph. Clean the vacuum
cleaner as described in the "Maintenance,
cleaning and decontamination" paragraph.
4 - Wash the container with clean water if aggressive
substances have been vacuumed.
5 - Store the vacuum cleaner in a dry place, out of
reach of unauthorized people.
6 - Shut the inlet with the appropriate plug "A" (fig.
14) when the vacuum cleaner is transported or
not being used (particularly in the case of M, H
versions).

Maintenance, cleaning and decontamination

DANGER !
IMPORTANT: the precautions described below
must be taken during all the maintenance
operations, including cleaning and replacing
of the primary and absolute filters.
a)
To allow the user to carry out the maintenance
operations, the vacuum cleaner must be
disassembled, cleaned and overhauled as far
as is reasonably possible, without causing
hazards for the maintenance staff or other
people.
The suitable precautions include
decontamination before disassembling the
vacuum cleaner, adequate filtered ventilation
of the exhaust air from the room in which it is
disassembled, cleaning of the maintenance
area and suitable personal protection.
b) If the vacuum cleaner belongs to the M
or H class, the external parts must be
decontaminated by cleaning and vacuuming
methods, dedusted or treated with sealant
before being taken out of a hazardous zone.
All parts of the vacuum cleaner must be
considered as contaminated when they
are removed from the hazardous zone and
appropriate actions must be taken to prevent
dust from dispersing. When maintenance
or repair procedure are carried out, all the
contaminated elements that cannot be
properly cleaned, must be eliminated.
These elements must be disposed of in sealed
bags conforming to the applicable regulations
and in accordance with the local laws
governing the disposal of such material.
This procedure must also be followed when
the filters are eliminated (primary and absolute
filters).
IMPORTANT: compartments that are not
dust-tight must be opened with suitable tools
(screwdrivers, wrenches, etc.) and thoroughly
cleaned.
10/2007
c)
In addition, the filtering effectiveness of class
H appliances should be checked at least once
a year or even more often if so specified by
national law. The filtering effectiveness of
the appliance can be tested following the
testing procedure explained in the norm DIN
EN 60335-2-69 AA.22.201.2. If the outcome is
negative the test has to be repeated with a new
primary filter.
d) ATTENTION: this appliance contains
powders that are harmful for one's health. All
maintenance work and emptying, including
removing the powder from the container, must
be done by specialized personnel only and
they must wear protective clothing. Do not
start without the complete filtering system in
place.
e)
This appliance is not to be used by people
(including children) with physical or sensorial
problems or mental difficulties or with little
education and/or knowledge who must
always be supervised by skilled people or
be instructed by them on how to use the
appliance.
DANGER !
Use only genuine spare parts supplied and
authorized by the manufacturer.
Main and HEPA filter disassembly and
replacement
DANGER !
When the vacuum cleaner is used to vacuum
hazardous substances, the filters become
contaminated, thus:
-
work with care and avoid spilling the
vacuumed dust and/or material;
-
place the disassembled and/or replaced filter
in a sealed plastic bag;
-
close the bag hermetically;
-
dispose of the filter in accordance with the
laws in force.
DANGER !
Filter replacement is a serious matter.
The filter must be replaced with one of identical
characteristics, filtering surface and category.
Otherwise the vacuum cleaner will not operate
correctly.
9