up together with the "+", "-" and "SET" key LEDs) . The "A0—"
parameter appears on the display.
Press the "SET
parameters until you reach the parameters from "t0—" to "t6—"
The following parameters can be changed using the "+" and
"-" keys:
t0—: set the current year from 00 to 99 (two digits);
t1—: set the current month from 01 to 12;
t2—: set the current day from 01 to 31;
t3—: set the current time from 00 to 23 (24 hours);
t4—: set the current minute from 00 to 59;
t5—: set summer time start month, from 00 to 12;
t6—: set return to standard time month, from 01 to 12;
"SET
automatically exit the programming procedure.
You can exit the programming procedure at any time by
pressing any key other than "ON/OFF", "+", "-" and "set", or
wait 30 seconds without pressing any key.
From standard to summer time: on the last Sunday of the
month set in the "t5" parameter (at 3 am), the time changes
from standard to summer.
parameter (at 3 am), the time goes back to standard time.
NOTE: By setting the parameter "t5=0", no time change is
made even if the "t6" parameter is different from "0".
To display the memorised date and time, press the "ON/OFF"
key on the display: the current temperature of the water in the spa
appears.
The following parameters are displayed by repeatedly pressing
the "MANUAL" key:
SP—: temperature at which to heat the water in the spa (in
°C or °F), or "set point
keys).
hh.mm: current time, in hours and minutes (00÷23).
dd.mm: current date, in day - month.
yyyy: current year (4 digits).
NOTE: to modify the date and time again, turn the system
off using the "ON/OFF" key and proceed as described in the
previous chapter.
PARAMETER SETTING MENU
To access the function SETTING MENU , the keyboard must be
in "COMMAND STAND-BY" mode.
Press the "LIGHT" key for a few seconds: the relative LED will
turn on as well as the "+", "-" and "set" key LEDs, while the
P0-" parameter. Repeatedly press the
"set" key to display all system general parameters in sequence.
The following parameters can be changed using the "+" and
"-" keys:
P0(-): system control mode (default=1).
0 = pneumatic buttons active (near the spa)
"electrical box").
P1(-):
(default=1).
0 = timer off,
the timer data.
system active
TIMER
P2(-): "set point" water heating temperature (default 36 °C
or 97 °F).
-
P3(-): "set point" hysteresis (default 1 °C or 2 °F).
P4(-): automatic whirlpool pump and blower activation time
(default 0).
0 = automatic function disabled (off).
The
t6—", you
P5(-): time interval for the automatic "P4(-)" whirlpool pump
and blower reactivation (default 15 min).
P4 = 0 no value can be entered on P5.
minutes.
P6(-): whirlpool pump and blower operation "timeout", when
activated using the pneumatic buttons (default 20 min).
t6"
the whirlpool pumps and the blower automatically switch-off.
0 = "timeout" disabled.
P7(-): temperature display in °C or °F (default 0).
0 = temperature in °C,
1 = temperature in °F.
P8(-):
+" and "-"
loading solenoid valve (default 30).
P9(-): system management through "token dispenser"
(default = 0).
0 = token dispenser disabled;
1 = token dispenser enabled.
PA(-): minimum water temperature "set point" (default 15 °C
or 59 °F).
The heating function activates (optional) if the water
temperature drops below the set "set point".
automatically exit the programming procedure.
You can exit the programming procedure at any time by
pressing any key other than "ON/OFF", "+", "-" and "set", or
wait 30 seconds without pressing any key.
WATER FILTRATION
manual"
When users in the spa turn on a whirlpool pump and/or the
a further 15 min after the whirlpool pump and/or the blower are
turned off). This eliminates polluting substances introduced in
the spa water by the users themselves.
spa is used often, setting time bands (Max. 3) over 24 hours.