Burners" Technical Data Table; Rules For Converting And Installing For Other Types Of Gas; Changing The Open Ring Nozzles; Main Nozzles (Fig. C) - Lotus cooker PC-94G Instructions Pour L'installation Et L'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Burner max 4 kW -min 1,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 7 kW -min 1,8 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 10 KW-min 2,3 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Oven Burner max 8,5 kW- min 2.2 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Oven Burner max 13 kW -min 3,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).

Main nozzles (Fig. C):

Take the rungs off, remove the burners and trays, with a size 12 spanner substitute the nozzles with the appropriate
ones, regulate the primary air (h) (see the "burner" technical data table) unscrewing the securing screw. Once regulated,
tighten the screw, adjust the minimum flame by turning the screw to the right or left until the thermal power reaches 1.5
kW for the 45 kW burner, 1.8 for the 7 kW burner and 2.3 kW for the 10 kW burner.
Caution: If liquid gas is being used the minimum adjustment screw must be locked right down.

Pilot nozzles (Fig. D):

Take the rungs off, remove the burners and trays, with a size 8 spanner loosen the nozzle holder unit, with a size 11
spanner unscrew the nozzle holder all the way, with a slotted screwdriver unscrew the pilot nozzle and replace it with
the appropriate one and tighten right down.
Put everything back in place and regulate the air by means of the adjusting bush until the pilot flame stops sputtering
and becomes an intense blue colour.
GB
IT

"BURNERS" TECHNICAL DATA TABLE

12.68 kWh/KG
G30
BUTANE
30 mbar
kg/h 0,315
kg/h 0,552
kg/h 0,789
kg/h 0,670
kg/h 1,025

CHANGING THE OPEN RING NOZZLES

IE
CH
12.87 kWh/KG
G31
PROPANE
37 mbar
95
95
60
60
20
20
kg/h 0,311
3
3
130
130
65
65
20
20
kg/h 0,544
open
open
155
155
75
75
20
20
kg/h 0,777
open
open
145
145
75
75
19
19
kg/h 0, 660
20
20
180
180
100
100
19
19
kg/h 1,010
25
25
44
3
9.45 kWh/m
st.
G20
NATURAL GAS H
20 mbar
145
adjustable
30
3
m
st./h 0,423
0
195
adjustable
35
3
m
st./h 0,740
1
230
adjustable
35
3
m
st./h 1,058
1
220
adjustable
27
3
m
st./h 0,899
20
290
adjustable
27
3
m
st./h 1,376
25