Installation Preparation

Installation Considerations

Clearances and requirements
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the applian-
ce's installation manual.
20
"
9
16
(522)
30" (762) min over a electric cooktop
30" (762) min over a gas cooktop
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing
must cover the entire cooking surface. Where space is
not restricted, a wider hood can be used to increase
capture area.
For proper performance, the hood must be centered
horizontally above the cooking surface.
Installation Instructions
Distance From Cooking Surface
For gas cooktop & range installations: Mount the hood
so the bottom is at least 30" (76.2 cm) above the cooking
surface.
For electric/induction cooktop & range installations:
Mount the hood so the bottom is at least 30" (76.2 cm)
above the cooking surface.
NOTICE: The hood could incur some damage from heat
if a THERMADOR MASTERPIECE
ted with multiple burners at high settings under a hood that
is installed at minimum clearances.
Unit Weight
This vent hood is heavy. Adequate structure and support
must be provided in all types of installations.
When calculating the load for the housing support
system, be sure to consider the weight of the
ventilation unit.
Unit
30'' (76 cm)
36'' (91 cm)
IMPORTANT:
The supplied weights address only the ventilation unit and
blower. Installer must account for weight of any materials
of construction when calculating the total dead weight
load of installation, including but not limited to: wall, tile,
mortar, plaster, brick, finishes, partitions, and other similar-
ly incorporated architectural and structural items. It is the
responsibility of the owner and the installer to determine if
additional requirements and/or standards apply to specific
installations.
series cooktop is opera-
®
Weight
50.2 lb (22.8 kg)
53.3 lb (24.2 kg)